   * Stratasys FDM 2000 3D printer with ABS head   * Stratasys FDM 2000 3D printer with ABS head
   * 1.75mm filament   * 1.75mm filament
-  * ABS or ABS+ plastic resin material (use _only_ Stratasys OEM filament or equivalent - ask Have Blue if unsure about material suitability)+  * ABS or ABS+ plastic resin material (use _only_ Stratasys OEM filament or equivalent such as Coex MG94 - ask Have Blue if unsure about material suitability)
   * Currently located in the 3D Printing Area   * Currently located in the 3D Printing Area
  
Line 15: Line 15:
   * See Have Blue for Insight 8.1 (Stratasys control software, last version to support the FDM series)   * See Have Blue for Insight 8.1 (Stratasys control software, last version to support the FDM series)
 =====Current Status ===== =====Current Status =====
-  * Head is disassembled and undergoing repair and reassembly.+  * Head has been rebuilt, support nozzle has been replaced.  Still needs calibration and tweaking.
   * Spare WinXP computer for running the machine has been acquired.   * Spare WinXP computer for running the machine has been acquired.
-  * Chip built a bottom shelf for the cart for storage of filament, parts, etc. 
 =====On loan from ===== =====On loan from =====
   * Have Blue   * Have Blue
Line 30: Line 29:
   * Late 2013/Early 2014 - disassembled head for removal of support extruder, support hotend cleaned, discovered manufacturing defect that should be easily fixed.   * Late 2013/Early 2014 - disassembled head for removal of support extruder, support hotend cleaned, discovered manufacturing defect that should be easily fixed.
   * 20APR2014 - fixed manufacturing defect in support hotend, polished internal passage, reassembled hotend with heater, thermocouple, inlet buffer, and fiberglass insulation.   * 20APR2014 - fixed manufacturing defect in support hotend, polished internal passage, reassembled hotend with heater, thermocouple, inlet buffer, and fiberglass insulation.
 +  * 21APR2014 - discovered that the head rebuild didn't do squat and it was still jamming.
 +  * 22APR2014 through 7MAY2014 - long, alcohol fueled depression (just kidding)
 +  * 8MAY2014 - replaced support nozzle; jamming eliminated.  Started Duchamp chess set print.
 +  * 9MAY2014 - print completed successfully and there was much rejoicing.  Commencing tweaking and calibration.
  