-====== Dust Particle Counter ====== +====== DIY Dust Particle Counter ====== 
-Based on: http://wiki.seeed.cc/Grove-Dust_Sensor/+ 
 +{{:projects:dustcounter:0715162344a.jpg?200|}}{{:projects:dustcounter:0721162314.jpg?200|}} 
 + 
 +Measures particulate matter at 1μm (one micron) diameter and calculates concentration in micrograms per cubic meter.   
 +Recommended exposure limits from various industry groups range from 5-15 mcg/m^3, 
 + 
 + 
 +Based on:  
 +  * http://wiki.seeed.cc/Grove-Dust_Sensor/ 
 +References: 
 +  * https://www.osha.gov/dts/chemicalsampling/data/CH_259640.html 
 +  * https://www.osha.gov/dsg/annotated-pels/tablez-1.html 
 + 
 +Test readings: 
 +  * 7/21/16 {{:projects:dustcounter:screen_shot_2017-05-07_at_7.19.13_am.png?300|}} 
 +  * 7/28/16 {{:projects:dustcounter:screen_shot_2017-05-07_at_12.15.47_am.png?300|}}  
 +  * 5/5/17 {{:projects:dustcounter:screen_shot_2017-05-07_at_7.07.56_am.png?300|}}