equipment:aircompressor [2018/08/12 02:35]
branth [History]
equipment:aircompressor [2022/12/18 21:06] (current)
tony3 Update instructions for Masterforce backup compressor
Line 24: Line 24:
  
 Procedure to turn on the backup compressor: Procedure to turn on the backup compressor:
-    1)  Push the red stop button the wall box+    1. Circuit breaker in hall panel turned on – 40A toward the top right of the panel
-    2)  Unplug the fat cord from the outlet to the left of the wall box +    2. Backup compressor plugged into the outlet on the wall. 
-    3)  Plug the backup compressor in +    3. Control box Estop switch out – rotate if its in. 
-    4)  Twist the red stop button to reset the system+    4. Main pressure switch to the right of the air tank on – Down is on, up is off. 
 +    5. Air dryer plugged in and running 
 +    6. Air drain plugged in 
 +    7. All valves open.
  
 Make sure the backup compressor starts and nothing is rattling around on it (bottles, tools, etc.) Make sure the backup compressor starts and nothing is rattling around on it (bottles, tools, etc.)
-Check back to make sure the backup compressor turns off when the system is pressurized, if it never turns off shut down the whole system.+Check back in about 5 minutes to make sure the backup compressor turns off when the system is pressurized, if it never turns offshut down the whole system.
 Always post to the message board when you do this. Always post to the message board when you do this.
  
-To reconnect the main compressor, just do the above steps swapping "main" and "Backup"+To run the main compressor
 + 
 +    1. Circuit breaker in hall panel turned on – 40A toward the top right of the panel. 
 +    2. Main compressor plugged into the outlet on the wall. 
 +    3. Control box Estop switch out – rotate if its in. 
 +    4. Main pressure switch to the right of the air tank on – Down is on, up is off. 
 +    5. Air dryer plugged in and running 
 +    6. Air drain plugged in 
 +    7. All valves open. 
 +    
  
  ===== Parts =====   ===== Parts ===== 
Line 97: Line 109:
 07/15/18 - 5140.4 read, avg. 1.79/day\\ 07/15/18 - 5140.4 read, avg. 1.79/day\\
 07/25/18 - 5155.5 read, avg. 1.51/day\\ 07/25/18 - 5155.5 read, avg. 1.51/day\\
-07/15/18 - 5191.5 read, avg. 2.12/day\\+08/11/18 - 5191.5 read, avg. 2.12/day\\ 
 +08/25/18 - 5213.4 read, avg. 1.56/day\\ 
 +10/05/18 - 5286.9 read, avg. 1.79/day\\ 
 +10/28/18 - 5323.9 read, avg. 1.61/day\\ 
 +11/14/18 - 5347.6 read, avg. 1.39/day\\ 
 +12/29/18 - 5427.9 read, avg. 1.78/day\\ 
 +01/12/19 - 5449.7 read, avg. 1.56/day\\ 
 +02/08/19 - 5490.2 read, avg. 1.50/day\\ 
 +03/22/19 - 5571.5 read, avg. 1.94/day\\ 
 +04/07/19 - 5604.0 read, avg. 2.03/day\\ 
 +07/11/19 - 5840.7 read, avg. 2.49/day\\ 
 +07/28/19 - 5880.3 read, avg. 2.33/day\\ 
 +10/27/19 - 6093.1 read, avg. 2.33/day\\ 
 +11/03/19 - 6107.8 read, avg. 2.10/day\\ 
 +12/30/19 - 6241.7 read, avg. 2.34/day\\ 
 +01/25/20 - 6304.0 read, avg. 2.39/day\\ 
 +01/01/21 - 6707.6 read, avg. 1.26/day\\ 
 +05/15/21 - 6707.6 read, avg. 0.00/day\\ 
 +07/05/21 - 6707.6 read, avg. 0.00/day\\ 
 +09/04/21 - 6707.6 read, avg. 0.00/day\\ 
  
 ===== Notes ===== ===== Notes =====