Central Air Compressor

Specs

  • Compressor Motor: Baldor M7170T, 10 HP, 208/3/60, max 125 PSIG
  • Dryer/Filter: Ingersoll-Rand TS-100, 125 CFM, 115v/1/60 Hz, 10 amp, air-cooled R-407C, max 25 HP, max 175 PSIG
  • Tank: Energair One, 100-gallon

Current Status

  • Back on-line
  • Small oil leak into air lines

If an air line springs a leak:

  1)  Fix the leak
  2)  If you can't fix the leak, turn off any valves that will isolate the leak.
  3)  If  you can't find a valve that will stop the leak turn the compressor off
  Post to the members list that there is a problem that needs fixing.

If the air compressor trips its breaker, overheats the room, or just hums and doesn't turn:

 Push the RED ESTOP button on the box on the wall next to the compressor
 Post to the members list that there is a problem

Procedure to turn on the backup compressor:

  1. Circuit breaker in hall panel turned on – 40A toward the top right of the panel.
  2. Backup compressor plugged into the outlet on the wall.
  3. Control box Estop switch out – rotate if its in.
  4. Main pressure switch to the right of the air tank on – Down is on, up is off.
  5. Air dryer plugged in and running
  6. Air drain plugged in
  7. All valves open.

Make sure the backup compressor starts and nothing is rattling around on it (bottles, tools, etc.) Check back in about 5 minutes to make sure the backup compressor turns off when the system is pressurized, if it never turns off, shut down the whole system. Always post to the message board when you do this.

To run the main compressor:

  1. Circuit breaker in hall panel turned on – 40A toward the top right of the panel.
  2. Main compressor plugged into the outlet on the wall.
  3. Control box Estop switch out – rotate if its in.
  4. Main pressure switch to the right of the air tank on – Down is on, up is off.
  5. Air dryer plugged in and running
  6. Air drain plugged in
  7. All valves open.
  

Parts

Tom's control box and e-stop
100-gallon tank with automatic drain valve, motor on tank is not operational
Refrigerated air dryer
10 HP compressor and motor

Location

Currently: Lenox, Vault 14
Previously: Chase building, in Loft

On lend from

History

12/01/10 - Arrived at Makerspace
10/10/11 - Motor needs repair, Rich Neubauer replaced the belt and fittings
12/31/12 - Moved to Lenox building
08/01/17 - Dryer offline for service
08/15/17 - Dryer back on-line, overheated and safety tripped off
08/15/17 - Transfer fan installed above door for ventilation
08/20/17 - 4030.5 hour meter read
08/22/17 - 4042.1 read, avg. 5.8 hrs/day
08/23/17 - 4048.6 read, avg. 6.5 hrs/day
09/02/17 - 4133.5 read, avg. 8.5/day
09/04/17 - 4150.4 read, avg. 8.45/day
09/09/17 - 4171.7 read, avg. 4.26/day
09/12/17 - 4183.9 read, avg. 4.06/day
09/17/17 - 4206.5 read, avg. 4.52/day
10/04/17 - 4278.9 read, avg. 4.26/day
10/08/17 - 4298.1 read, avg. 2.30/day
10/10/17 - 4307.0 read, avg. 4.55/day
10/15/17 - 4323.3 read, avg. 3.26/day
10/16/17 - 4328.2 read, avg. 4.90/day
10/18/17 - 4335.8 read, avg. 3.80/day
10/22/17 - 4351.7 read, avg. 3.98/day
10/31/17 - 4394.8 read, avg. 4.78/day
11/07/17 - 4430.6 read, avg. 5.11/day
11/11/17 - 4445.9 read, avg. 3.83/day
11/15/17 - 4460.0 read, avg. 3.53/day
11/18/17 - 4471.5 read, avg. 3.83/day
11/25/17 - 4504.0 read, avg. 4.64/day
12/10/17 - 4565.5 read, avg. 4.10/day
12/11/17 - 4570.0 read, avg. 4.50/day
01/01/18 - 4671.1 read, avg. 4.81/day
01/06/18 - 4686.1 read, avg. 3.00/day
01/13/18 - 4706.2 read, avg. 2.51/day
01/21/18 - 4727.0 read, avg. 2.97/day
01/24/18 - 4739.2 read, avg. 4.06/day
02/04/18 - 4771.1 read, avg. 2.90/day
02/16/18 - 4803.3 read, avg. 2.68/day
03/18/18 - 4870.5 read, avg. 2.92/day
03/26/18 - 4888.2 read, avg. 2.53/day
04/09/18 - 4945.8 read, avg. 2.74/day
04/18/18 - 4965.8 read, avg. 2.00/day
04/22/18 - 4976.7 read, avg. 2.72/day
05/12/18 - 5024.5 read, avg. 2.39/day
06/02/18 - 5065.9 read, avg. 1.97/day, sandblaster down
06/24/18 - 5102.9 read, avg. 1.68/day, sandblaster repaired this week
07/15/18 - 5140.4 read, avg. 1.79/day
07/25/18 - 5155.5 read, avg. 1.51/day
08/11/18 - 5191.5 read, avg. 2.12/day
08/25/18 - 5213.4 read, avg. 1.56/day
10/05/18 - 5286.9 read, avg. 1.79/day
10/28/18 - 5323.9 read, avg. 1.61/day
11/14/18 - 5347.6 read, avg. 1.39/day
12/29/18 - 5427.9 read, avg. 1.78/day
01/12/19 - 5449.7 read, avg. 1.56/day
02/08/19 - 5490.2 read, avg. 1.50/day
03/22/19 - 5571.5 read, avg. 1.94/day
04/07/19 - 5604.0 read, avg. 2.03/day
07/11/19 - 5840.7 read, avg. 2.49/day
07/28/19 - 5880.3 read, avg. 2.33/day
10/27/19 - 6093.1 read, avg. 2.33/day
11/03/19 - 6107.8 read, avg. 2.10/day
12/30/19 - 6241.7 read, avg. 2.34/day
01/25/20 - 6304.0 read, avg. 2.39/day
01/01/21 - 6707.6 read, avg. 1.26/day
05/15/21 - 6707.6 read, avg. 0.00/day
07/05/21 - 6707.6 read, avg. 0.00/day
09/04/21 - 6707.6 read, avg. 0.00/day

Notes