This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
projects:lasercutterventingsystem [2024/04/01 03:43] branth |
projects:lasercutterventingsystem [2024/04/01 04:25] (current) branth [Verison 7.0 - August 2023 - Present] |
||
---|---|---|---|
Line 59: | Line 59: | ||
{{: | {{: | ||
+ | === Fan Motor Drive (VFD) Settings === | ||
+ | * p031 motor nameplate volts = 230 | ||
+ | * p032 motor nameplate hertz = 60 | ||
+ | * p033 motor overload current = 6.0 (motor nameplate is 5.4) | ||
+ | * p034 min freq hertz = 0 | ||
+ | * p035 max freq hertz = 60 | ||
+ | * p036 start source = digital input | ||
+ | * p037 stop source = digital input | ||
+ | * p038 speed ref = internal pot/knob | ||
+ | * p039 accel time = 30 sec | ||
+ | * p040 decel time = 5 sec | ||
+ | * p041 reset defaults = no | ||