Line 59: Line 59:
 {{:projects:laserlabexpansion:pxl_20230827_185343323_copy.jpg?100|}} {{:projects:laserlabexpansion:pxl_20230827_185343323_copy.jpg?100|}}
  
 +=== Fan Motor Drive (VFD) Settings === 
 +   * p031 motor nameplate volts = 230 
 +   * p032 motor nameplate hertz = 60 
 +   * p033 motor overload current = 6.0 (motor nameplate is 5.4) 
 +   * p034 min freq hertz = 0 
 +   * p035 max freq hertz = 60 
 +   * p036 start source = digital input 
 +   * p037 stop source = digital input 
 +   * p038 speed ref = internal pot/knob 
 +   * p039 accel time = 30 sec 
 +   * p040 decel time = 5 sec 
 +   * p041 reset defaults = no
  
  